Partial Discharge
453 Followers
Recent papers in Partial Discharge
Partial discharge (PD) spectral response to variations in the supply voltage frequency was experimentally investigated through laboratory-based tests. The PD spectral content of each defect type responded uniquely to variations in the... more
Using available expert knowledge in conjunction with a structured process of data mining, characteristics observed in condition monitoring data (which represent modes of plant operation) may be understood, explained and quantified.... more
Partial discharge measurements on transformers and rotating machines are an accepted tool of quality control, in factory and on site. Common methods to improve the quality of noisy PD data are filtering and gating. Recently a new method... more
An important obstacle in the life expectancy of high voltage equipment is the progressive and systematic damage to insulation systems caused by Partial Discharge (PD). The evolution of PD activity is symptomatic of the insulation state.... more
Partial discharge (PD) measurements conducted in the high voltage (HV) laboratory are less affected by electromagnetic disturbances (EMD). However, on the other hand, online/on-site PD measurements are often affected by several EMD... more
Partial discharge measurements on transformers and rotating machines are an accepted tool of quality control, in factory and on site. Common methods to improve the quality of noisy PD data are filtering and gating. Recently a new method... more
the pattern of partial discharge (PD) occurrence at a defect site within a solid dielectric material is influenced by the conditions of the defect site. This is because the defect conditions, mainly its size and location determine the... more
The detection and localisation of partial discharge (PD) activities is gaining importance in maintaining operational transformers and diagnosing those which are faulty. Ultra-high-frequency (UHF) techniques have been applied successfully... more
In this paper, we present the electrical and mechanical behaviour of Cross-Linked Polyethylene (XLPE), used as electrical insulation in high voltage cables, under thermal ageing. Continuous accelerated thermal ageing tests on 18/30kV XLPE... more
There has been a considerable amount of discussion concerning partial discharge (PD) measurements on medium voltage motors and generators. If one considers the total plant electrical distribution system and production equipment, motors... more
Partial discharge technology has been applied to medium voltage rotating machines for many years. This technology can now be applied to support on-line diagnostics of medium voltage switchgear assemblies. Partial discharge sensors have... more
An ultracapacitor bank control system for an Electric Vehicle has been simulated. The purpose of this device is to allow higher accelerations and decelerations of the vehicle with minimal loss of energy, and minimal degradation of the... more
It is important to detect decomposition of insulating gas SF6 caused by partial discharges for gas-insulated switchgear (GIS). In the previous result, the author developed a novel partial discharges sensing using carbon nanotube (CNT) gas... more
Condition-based monitoring (CBM) has been a vital engineering method to assess high voltage (HV) equipment and power cables conditions or health levels. One of the effective CBM methods is partial discharge (PD) measurement or detection.... more
As shown in recent papers, Partial Discharge activity has a fundamental role in the premature failure of electrical insulation of machine stator windings fed by PWM inverters. The existence of Partial Discharges can be easily explained if... more